Find Your Vent Size: Duct Opening to Vent Cover Chart
Quick answer: Vent covers are sold by the size of the duct opening (the hole in the floor, wall or ceiling), not the size of the old cover. Remove the old cover, measure the hole width × length in inches, and buy that size. A 4x10 opening takes a 4x10 vent cover, whose face is larger so it overlaps the edges of the hole.
Step 1: Measure the hole, not the cover
- Take off the old register or grille (usually 2 screws, or it lifts out on floors).
- Measure the inside of the opening: short side first, then long side. A 4" × 10" hole is a "4x10" size; 10x4 is the same size.
- If you land between sizes, use the nearest standard size. A hole that is about 1/4" bigger or smaller is normal. Full guide: How to Measure Your Vent.
- Check what the opening does: supply (air blows out) or return (air is pulled in). That decides the type of cover.
Step 2: Match the opening to a Green Vent cover
| Duct opening (inches) | Floor supply | Floor return | Wall / ceiling return (with filter) | Linear slot diffuser (ceiling, wall) |
|---|---|---|---|---|
| 4x6 · 6x6 · 4x8 · 6x8 · 8x8 | — | — | 4x6 · 6x6 · 8x8 | 4x6 · 6x6 · 4x8 · 6x8 · 8x8 |
| 4x10 (most common floor size) | Floor register, black · gray · white | Floor return grille, black · gray · white | 4x10 | 4x10 white · 4x10 black · 4x10 Slim |
| 6x10 · 8x10 · 10x10 | — | — | 6x10 · 10x10 | 6x10 · 8x10 · 10x10 |
| 2x12 · 4x12 · 6x12 · 8x12 · 12x12 | — | — | 6x12 · 12x12 | 2x12 · 4x12 · 6x12 · 8x12 · 12x12 |
| 2x14 · 6x14 · 8x14 | — | — | 6x14 | 2x14 · 6x14 · 8x14 |
Linear slot diffusers in 4" and 2" widths can also go in the floor. Browse by type: floor vent covers · 4x10 vent covers · return air vents with filter · linear slot diffusers · all air vent covers.
Step 3: Check the face and the fit
- The cover face is bigger than the size name. Example: the 4x10 aluminum floor register has a 12" × 6" face that rests on the floor around a 4" × 10" hole.
- Floor registers drop into the hole, so the neck must fit inside the opening. Measure the inside edges, not the flooring cut-out above them.
- Not sure? Try the interactive Vent Finder or check the spec sheets.
Vent size FAQ
Do I measure the vent cover or the hole?
The hole. Vent cover sizes name the duct opening. A cover labeled 4x10 fits a 4" × 10" opening and its face is larger.
Is 10x4 the same as 4x10?
Yes. The two numbers are the same opening; stores just list them in a different order.
My hole is 4-1/4" × 10-1/4". Which size do I buy?
Buy 4x10. Openings are often cut a little oversized; the cover face overlaps the gap.
What is the most common floor vent size?
4x10 is the most common floor register size in US homes, followed by 4x12 and 2x12.
How do I know if a vent is supply or return?
Turn the system fan on. If air blows out, it is a supply vent. If a sheet of paper is pulled flat against it, it is a return. Returns are usually larger and often on walls or hallways.